beautypg.com

Table 2: pl-50 power controller – monitor features, Table 2, Your pl-50 power controller - monitor – Kramer Electronics PL-50 User Manual

Page 10

background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Your PL-50 Power Controller - Monitor

6

Table 2: PL-50 Power Controller – Monitor Features

#

Feature

Function

1

IR Receiver Window

The red LED lights when receiving signals from the Kramer

Infrared remote control transmitter

2

POWER LED

The red LED lights when the main power is ON

3

OUT Channel

(from 1 to 5)

STANDBY LED The orange LED lights when the channel outlet is in the

standby mode, and blinks when reading the standby level

4

ACTIVE LED

The green LED lights when an outlet is connected to that

power channel and active, and blinks when reading the preset

active level

5

OUT Button

Press one or more buttons to select the power channel for

calibrating

6

PRESET LEVEL

Buttons

STANDBY

Press to read the standby mode

7

ACTIVE

Press to read the active mode

8

PROGRAM USB connector

For configuring and programming the unit

9

ETHERNET Connector

Connects to the PC or other Serial Controller through computer

networking

10

RESET

Press to reset the standby and active values for all the

channels, as well as the security passwords

11

RS-232 9-pin D-sub Port

Connect to the PC or other Serial Controller

12

DIP-switches

Program, for technical use only

RS-485 TERM, for RS-485 termination

13

RS-485 Terminal Block Connector Connect to the PC or other Serial Controller

14

RELAY terminal block connector

Connect to an alarm or other item (see section

6.1

)

15

DIGITAL CONTROL (G, OC

1

Connect to an alarm or other item

)

Terminal Block Connector

16

Power Outlets (from 1 to 5)

220-240V AC for European version (see

Figure 2

)

100-120V AC for USA version (see

Figure 3

)

17

POWER IN Connector with FUSE

AC connector enabling power supply to the unit

18

POWER Switch

Illuminated switch supplying power to the unit

1 OC means Open Collector