Status_Word
CI access
6041h
00h
Var
uint16
r
Description
Download current controller or regulator status.
Typical values see Tab. B/2.
Default: 0x0031
Bits 0...3, 5 and 6 show the status of the device.
Value (binary)
Status (x = irrelevant for this status)
xxxx xxxx x0xx 0000
Not ready to switch on
xxxx xxxx x1xx 0000
Switch on disabled
xxxx xxxx x01x 0001
Ready to switch on
xxxx xxxx x01x 0011
Switched on
xxxx xxxx x01x 0111
Operation enabled
xxxx xxxx x00x 0111
Quick stop active
xxxx xxxx x0xx 1111
Fault
Bit
Value
Comment
Mask open ...
—
0x0000
Not ready to switch on (pre-initialization status)
—
—
0x0021
Ready to switch on (status after initialization)
—
—
0x0027
Switched on + operation enable (power electronics and
positioning are enabled)
—
3
0x000F
Fault (there is a fault)
Bit 3: 0x0008
4
0x0010
<1>: Voltage disabled (end stage off)
<0>: Voltage enabled (end stage on)
Bit 4: 0x0010
10
0x0400
Nominal position reached
<1>: Target reached /Motion Complete (see also Object 6068)
<0>: Motion not complete
Bit 10: 0x0400
11
0x0800
I
2
t-fault
<1>: Internal limit active
<0>: Internal limit not active
Bit 11: 0x0800
13
0x2000
Fault during homing run
<1>: Homing error
<0>: No homing error
Bit 13: 0x2000
Tab. B/2:
Typical values of status word