5

Commissioning

68

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

Binary profile: Outputs

DOUT

Designation

Description

1

Motion complete

Target position, target force or target speed reached.

2

1)

ACK/TEACH

Confirmation of the start of a record

- or -

confirmation of successful teaching

3

1)

PAUSE (Stopped)

The drive has been stopped.

4

Moving

The drive moves.

5

1)

Alarm (Error)

An error has occurred.

6

Configurable

Different signals can be allocated to these outputs by using FCT.

7

8

In Zone

The drive is located within the configured position zone of the

current position record, i.e. within the position comparators.

9

Referenced

The drive is referenced.

10

Ready

The drive is ready for operation.

11

Torque limit reached

Target force reached. Only for positioning and speed mode.

1)

The output is inverted, i.e. the message is issued through logic 0.

Tab. 5.7

Binary profile: Outputs