beautypg.com

Air power pack maintenance – Hawk Industries Spinner Manual 550 HYDRAULIC Serial Numbers 1 to 205 User Manual

Page 36

background image

36

Maintenance & Repair

1. The hydraulic tank should be

cleaned approximately once
every year
of service.

2. Remove the lock strap from the

tank valve (TV) and rotate
clockwise
to the off position.

2. Drain the hydraulic tank first by

removing the pump end of the
pump suction hose (PSH).
Rotate the tank valve (TV) to the
on position and drain off old oil.

3. Unscrew the other end of the

pump suction hose from the tank
valve (TV), and remove the tank
valve and the suction strainer
inside the tank, by unscrewing
the tank valve at the fitting (TF)
just adjacent to the tank.

4. Thouroghly clean the suction

strainer (SS) with cleaning
solvent. Replace if damaged.

5. Flush out the tank with cleaning

solvent and remove sludge build-
up on the bottom of the tank.

6. Re-install all components.
7. Replace return line filter. See

prior page.

8. Fill the tank with clean oil.
9. Make sure the tank valve (TV) is

turned on (the position shown in
above photo). Lock the valve in
the on position with wire.

Change Suction Strainer

PSH

TF

TV

Air Power Pack Maintenance

Part Name

Part #

Suction Strainer (SS)

031-P04A

Part Numbers

SS