Air power pack maintenance, Warning – Hawk Industries Spinner Manual 550 HYDRAULIC Serial Numbers 1 to 205 User Manual

Page 31

background image

31

Maintenance & Repair

Air Power Pack Maintenance

SG

FP

1. Check oil level at least once per

day using oil level sight gage
(SG) .

2. To add oil to the air lubricator,

remove filler plug (FP).

3. Use a small funnel and fill

lubricator with #10 wt. pneu-
matic oil
up to the filler cap.

4. Replace filler cap.

The Air Spinmaster air
motors (Main Motor &
Power Pack Motor) must be
lubricated to provide de-
pendable service. Air
motors will rust up on the
inside and lock up if not
lubricated
.

WARNING

Filling Air Lubricator