Lubrication – Hawk Industries Spinner Manual 550 HYDRAULIC Serial Numbers 1 to 205 User Manual
Page 22

22
Maintenance & Repair
Lubrication
RP
1. Make sure the gear box oil level
reaches the top pipe plug (RP).
2. Check for any oil leakage from
the gear box seal by looking at
the top or the drive shaft.
Lubricant Required
85-90 weight gear oil
SAE #AGMA5
Check Oil Level Once per Month
Reducer Gear Box
MGV
MGF
Grease after overhaul
1.Remove motor grease vent plug
(MGV). Use a grease gun to fill
the air motor gear box at the
motor grease fitting (MGF) until
grease begins to flow from the
vent (MGV).
2. Replace the vent plug (MGV).
Lubricant Required
Lithium Base #2 High Temperature
Grease. Use Lo-Temp Grease in
temperatures -20 deg. F or below.
Air Motor Gear Box
NOTE
Consistent lubrication of the Spinner
increases performance and
componnent life.
This manual is related to the following products: