HT instruments HT710 User Manual
Page 36

HT710
EN - 14
6.1.7. Electrical
Conversion: Average
value
Display refreshing rate:
3 times per second
6.1.8. Safety
The instrument complies with:
EN 61010-1
Insulation:
Class 2, Double insulation
Pollution degree:
2
Overvoltage category:
Category IV 600 V
For inside use, max height:
2000m
6.1.9. General
data
Mechanical characteristics
Dimensions:
250(L) x 51(W) x 30(H)mm
Weight (including batteries):
approximate 150g
Power supply
Battery type:
2 batteries 1.5V AAA MN2400 LR03 AM4
Indication of low batteries:
"
" is displayed when batteries voltage is too low
Battery life:
Approximate 200 hours
Display
Type:
3 ¾ digits LCD with max. reading 3999 counts +
symbol and decimal point
6.2. ENVIRONMENT
6.2.1. Environmental
conditions
Reference temperature:
23 ± 5°C
Working temperature:
5 ÷ 40°C
Relative humidity:
<80%RH
Storage temperature:
-10 ÷ 60°C
Storage humidity:
<70%RH
6.2.2. EMC and LVD
This product conforms to the prescriptions of the European directive on low voltage
2006/95/EEC (LVD) and to EMC directive 2004/108/EEC.
6.3. ACCESSORIES
6.3.1. Standard
accessories
The accessories contained inside the packaging are the following:
• Instrument
• Red test lead
Code: P711EU
• Black test lead
Code: P710EU
• Instruction
manual
• Bag
Code:
B700
• Batteries
Note: accessories whose part number is not mentioned can not be reordered separately.