5.3 Pre-installation Preparation
5.3.1 Tools
Before installing the SRM series industrial monitor, make sure the following tools are on
hand:
Phillips (crosshead) screwdriver: All the retention screws on the system are
Phillips screws.
Soft working mat: When the SRM series industrial monitor is installed, the
screen is placed on the working surface. It is therefore important to rest the
MPC industrial workstation on a soft at that cannot damage the LCD screen
on the front of the SRM series industrial monitor.
5.3.2 Voltage Select Jumper Settings
If the monitor comes with both 12V and 9 ~ 36V DC power connectors, the voltage select
jumper on the integrated AD board must be configured for the DC connector that is used
to power the monitor.
NOTE:
The default voltage select jumper is configured for a 12V power source.
Do not change the jumper setting unless a 9~36V DC power connector
is to be used as the monitor’s power source.
To properly set the voltage select jumper, the following steps must be completed:
Step 1:
Use a screwdriver to remove all the screws holding the rear panel to the monitor.
Step 2:
Remove the rear panel.
Step 3:
Locate the voltage select jumper.