Chapter 4: System Setup and Wiring (Rev. 6:10/09)
Page 4-29
4.9 MON. Connector - External Torque/Angle/Current/Speed OUTPUT
This auxiliary connector is used to output Torque, Angle, Current & Speed signals to external
equipment for monitoring purposes (X-Y Plotter, etc). The signals output from this con-
nector are the same signals that the system receives during the fastening process. This
connection is not required for the system to operate.
FIG. 4-9a MON connector
Mating Connector: Molex #39-01-2065 Pin # 30-00-0047
PIN
Signal
Description
1
Torque voltage
Torque voltage monitoring output. (-5V to +5V).(2.5V full
scale shift)
2
Angle pulse
Angle pulses monitoring output (TTL, IOL = 30 ma).
3
Angle CW/CCW
Forward/Reverse pulse monitoring output (TTL, IOL = 30
ma).
4
Current voltage
Current voltage monitoring output (1.2Apeak/V).
5
Speed voltage
Speed voltage monitoring output (1000rpm/V [motor speed]).
6
Signal ground
Common for all output signal.
IOL = Current Output Low
Angle and direction are output as shown below.
FIG. 4-9b T/A OUT signal reference
6
3
5
4
2
1
CW/CCW
PULSES
ANGLE
ROTATION
TOOL
STOP
CW
CCW