beautypg.com

GxT V095-01 Automotive Analyzer User Manual

Page 8

background image

8

98

9

LOBAT

MAX
MIN

Ω

HOLD

Continuity Display

Ohms

The highest Ohms range
allows up to 40M Ohms
to be measured. All of the
ranges except the lowest

use a low current source that will not
forward bias semiconductor junctions.
The lowest Ohms range does use
source current that can cause
semiconductor junctions to conduct
and affect the readings.

The Diode Volts range will measure
semiconductor junction voltages up to
1.999 In the reverse direction an OFL
indication is expected.

The continuity test, indicated by both
the beeper symbol and the Ohms
symbol being active, uses the lowest
Ohms range. Anytime the reading goes
below 100 the beeper will sound.

Note: The meter is equipped with a self
protection device that will protect the
ohms function in case the test leads
are connected to battery voltage.

Supported Functions:

Ohms

88

3

LOBAT

MAX
MIN

AUTO

M

Ω

HOLD

REL 0

Ohms Display

88

4

LOBAT

MAX
MIN

HOLD

Diode Display

HOLD

Min

Max Range

REL

Zero