beautypg.com

GxT V095-01 Automotive Analyzer User Manual

Page 11

background image

11

Volts • Amps

Pressing the button will
cycle you through the
Volts•Amps Display and a
Battery/Starter Test. The

High range amp probe is used during
this test. The Volts•Amps function
displays Amps on the top display, and
battery voltage on the bottom display.

The Battery/Starter Test will display a Crank Engine message
(CrnEng). To set up the test, connect the test leads to the vehicle
battery terminals, and place the Amp Probe onto the negative
battery cable, and disable the ignition. To start the test, crank
the engine. After 15 seconds of cranking the freeze readings will
freeze

Supported Functions:

V•A

HOLD Range

Volts Amps Display

38

2

88

0

1

LOBAT

MAX
MIN

AMPS

V

HOLD