I-View FAC – 500 FingerKey Access Controller DVR User Manual
Page 17

16
1).
Connecting method for power supply adapter serving for both FingerKey
and door lock contemporarily.
1. Matching voltage of lock must be 9 to 5V
2. Matching voltage of adapter must be accordant with that of lock.
3. Matching output current of adapter must exceed the working current by over
1000mA.
GND GND
+12V Power
RS232 RXD
Lock COM
RS232 TXD
Lock NO
GND
Lock NC
RS485 A
GND RS485
B
Alarm+
GND
Alarm— DATA0
Button DATA1
GND +5V
Output
Bell+
Door Sensor
Bell— GND
Power supply adapter -
12V +
+
Lock