B.3 freset clear selected data from nvm and reset, Freset clear selected data from nvm and reset – Novatel GNSS Receiver and Antenna SMART-AG User Manual
Page 69
SMART-AG User Manual Rev 5
69
B.3 FRESET Clear Selected Data from NVM and Reset
The OEMV freset command is extended to include SMART-AG features. An additional target field,
userdata (value = 10), resets only the SMART-AG user data NVM, thereby resetting all parameters
indicated in this document as “Stored in NVM” to factory defaults. Issuing the freset command with
the “target” field set to standard, resets the userdata NVM as well as OEMV parameters as indicated
in the OEMV Family Firmware Reference Manual.
Issuing the FRESET command affects Tilt as follows:
•
Tilt sensor level is restored to the factory default
•
Tilt enable/disable will not be affected
If you issue the FRESET command without any parameters, it is the same as
issuing a FRESET STANDARD command.
Field
Field
Type
ASCII
Value
Binary
Value
Description
Binary
Format
Binary
Bytes
Binary
Offset
1
FRESET
header
-
-
This field contains the
command name or the
message header
depending on whether the
command is abbreviated
ASCII, ASCII or binary,
respectively.
-
H
0
2
target
See Table 13,
Data to be reset by the
receiver
Enum
4
H