Table 10: COM Serial Port Identifiers
Table 11: Parity
Watch for situations where the COM ports of two receivers are connected
together and the baud rates do not match. Data transmitted through a port
operating at a slower baud rate may be misinterpreted as break signals by the
receiving port if it is operating at a higher baud rate.
This is because data transmitted at the lower baud rate is stretched relative to the
higher baud rate. In this case, configure the receiving port to have break
detection disabled using the COM command.
Binary
ASCII
Description
1
COM1
COM port 1
2
COM2
COM port 2
3
COM3
COM port 3
6
THISPORT
The current COM port
8
ALL
All COM ports
9
XCOM1
a
a.
The XCOM1, XCOM2 and XCOM3 identifiers are not
available with the COM command but may be used with
other commands.
Virtual COM1 port
10
XCOM2
a
Virtual COM2 port
13
USB1
b
b.
USB is not available on the SMART-AG.
USB port 1
14
USB2
b
USB port 2
15
USB3
b
USB port 3
16
AUX
AUX port
17
XCOM3
a
Virtual COM3 port
Binary
ASCII
Description
0
N
No parity (default)
1
E
Even parity
2
O
Odd parity