Electrical specifications, Environmental specifications, Table c-1 – Nortel Networks Passport ARN Routers User Manual
Page 126
Installing and Operating Passport ARN Routers
C-2
114200-E Rev 00
If you are installing your ARN in an electronic equipment rack, make sure that the
rack meets the following specifications:
•
Heavy-duty steel construction
•
Electronic Industries Association (EIA) standard hole-spacing
•
Width of 19 in. (48.26 cm)
•
Depth of 24 in. (60.96 cm)
Electrical Specifications
Your installation site must meet the following power requirements:
•
Proximity to wall receptacle: within 6 ft (1.8 m) of the ARN
•
Voltage: 100 to 240 VAC
•
Amperage: 0.5 to 1.0 A
lists the wall outlet requirements.
Environmental Specifications
The environmental requirements of the ARN are as follows:
•
Altitude: 0 to 8,000 ft (0 to 2,438.4 m)
•
Humidity: 10% to 90%, noncondensing
•
Temperature: 32
°F to 104°F (0°C to 40°C) stable
Table C-1.
ARN Wall Outlet Requirements
Country
Outlet
Voltage
United States/
Canada
National Electrical Manufacturers
Association (NEMA) 5-15P standard outlet
100 to 120 V
Any other country Your ARN distributor informs you of the
outlet you need.
200 to 240 V