Example Frames
144
PT Program Generator (PPG) v5.0
Figure 116. The Input: STORE Dialog
Figure 117. The Verify: SIZE Dialog
Verify: EXIT
Checks to see if the user pressed
. If so, it exits the frame.
Verify: SIZE
Checks the value stored in the
Input Size
register. The options in its
dialog box are set as shown in
Copy: TO FILE
Copies the scanned code from the default register into a file and loops
back to the
Input: STORE
node if the
Input Size
value is within the
given range (
6
to
10
) so that further codes can be scanned.
Display: WRONG Displays
INCORRECT INPUT; REENTER
if the
Input Size
value is
outside the defined range, on the portable’s screen and loops back to
the
Input
node so that the code can be scanned again.