Shure DP11EQ User Manual
Page 28
27
English –
Weight
930 g (2.05 lbs)
DYNAMICS PROCESSOR
Gate and Expander
Threshold: –72 to –1 dB, 0.5 dB resolution
Attack: 1.0 to 200 ms
Decay: 0.05 to 1 second
Gate Hold Time: 0 to 0.5 seconds
AGC Leveler
Threshold: –72 to –1 dB, 0.5 dB resolution
Attack: 0.2 to 3 seconds
Decay: 0.5 to 5 seconds
Hinge: Threshold to –1 dB, 0.5 dB resolution
Compressor and Limiter
Threshold: –72 to –1 dB, 0.5 dB resolution
Attack: 1.0 to 200 ms
Decay: 0.05 to 1 second
Knee: Hard or Soft selectable
No Overshoot Peak Limiter
Propagation delay: 1 ms
Threshold: –72 to –1 dB, 0.5 dB resolution
Attack: 0 ms
Decay: 100 ms
PARAMETRIC EQUALIZER
Parametric Filter Frequency Bands
Up to 9 bands, variable frequency, variable Q
Boost/Cut Range
+6 dB to –18 dB per band
Q Range
1
/
40
-octave to 2 octave
High and Low Shelf/Cut Filters
Shelf, +6 to –18 dB per filter
Cut, –12 dB per octave nominal
DELAY
Up to 1.3 seconds, 21 microsecond resolution
FURNISHED ACCESSORIES
Power Cable (DP11EQ )
95A8389
. . . . . . . . . . . . . . . .
Power Cable (DP11EQE)
95A8247
. . . . . . . . . . . . . . . .
5-pin DIN Shure Link Cable
95A8676
. . . . . . . . . . . . . .
Single Mount Rack Bracket
53A8484
. . . . . . . . . . . . . .
Dual Mount Rack Bracket
53B8484
. . . . . . . . . . . . . . .
Straddle Bars
53A8443
. . . . . . . . . . . . . . . . . . . . . . . . . .
SERVICE STATEMENT
For additional service or parts information, please
contact Shure’s Service department at
1-800-516-2525. Outside the United States, please
contact your authorized Shure Service Center.
CERTIFICATIONS
DP11EQ : UL L
ISTED
and cUL L
ISTED
to UL 813 and
CSA C22.2 No. 1. Authorized under Verification
provision of FCC Part 15 as a Class B Digital Device.
DP11EQ E: Conforms to European Union Directives,
eligible to bear CE marking. Meets European Union
Low Voltage Requirements: VDE GS-Certified to EN
60 950. Meets European Union EMC Emissions
Requirements: EN 50 081-1 (1992) [EN 55022].
Meets European Union EMC Immunity Requirements
EN 50 082–1 (1992).
INFORMATION TO USER
Changes or modifications not expressly approved by
Shure Inc
orporated
could void your authority to
operate this equipment.
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
S
Reorient or relocate the receiving antenna.
S
Increase the separation between the equipment
and receiver.
S
Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
S
Consult the dealer or an experienced radio/TV
technician for help.