beautypg.com

0 fault finding – Ingersoll-Rand NIRVANA IRN75-160K-2S User Manual

Page 95

background image

IRN37 - 160K - CC & IRN50 - 200H & IRN75 - 160K - 2S & IRN - 100 - 200H - 2S & IRN 250 - 300H - 2S

http://air.irco.com

3

11.0 FAULT FINDING

SYMPTOM

FAULT

REMEDY

Pressure produced
by compressor is too
highcompressor is too high
due to speed not reducing as
demand reducesreduces

Intellisys set incorrectly

Check and modify settings

Pressure transducer may be
faulty, incorrectly calibrated or
not receiving pressure signal

Recalibrate or replace

Drive settings fault

Contact your local IR representative

Compressor discharge air too
hot

High ambient temperature

Review installation and system parameters

Insufficient cooling air

Check ducting and cooling air path, check
direction of blower rotation

Blocked aftercooler matrix

Clean or replace

Compressor package produces
excessive noise

Panels or doors are not closed
properly

Rectify fault

Air leaks from internal pipework /
components

Overhaul or replace

Blower or blower motor bearings
worn

Overhaul or replace

Loose debris impacting on
blower during rotation

Remove and rectify any damage

Blowdown valve stuck open

Overhaul or replace

Pressure relief valve not seating
correctly

Overhaul or replace

Vibration due to motor, airend or
blower imbalance

Overhaul or replace

Airend requires overhaul

Contact your local IR representative

Discharge air is contaminated
with coolantcoolant

Scavenge pipe is blocked, broken
or o−ring is not sealing

Clean or replace

Separator element is punctured,
or incorrect, or requires changing,
or not sealing correctly

Replace

Incorrect coolant has been added Drain system, check for damage. Clean, refill

with correct coolant.

System has been overfilled with
coolant

Check for damage, drain excess.