beautypg.com

Ingersoll-Rand NIRVANA IRN75-160K-2S User Manual

Page 61

background image

IRN37 - 160K - CC & IRN50 - 200H & IRN75 - 160K - 2S & IRN - 100 - 200H - 2S & IRN 250 - 300H - 2S

http://air.irco.com

5

8.0 GENERAL INFORMATION

KEY

1ATS

SWITCH, HIGH AIR END DISCHARGE

TEMPERATURE

1ATT

SENSOR, INLET TEMPERATURE

1DPS

SWITCH, FOULED OIL FILTER

1VAC

SWITCH, FOULED AIR FILTER

2APT

SENSOR, INTERSTAGE PRESSURE (2STG ONLY)

2ATT

SENSOR, AIREND DISCHARGE TEMPERATURE

2CTT

SENSOR, INJECTED COOLENT TEMPERATURE

3APT

TRANSDUCER, SUMP PRESSURE, WET SIDE

3SV

VALVE, BLOWDOWN SOLENOID

4APT

TRANSDUCER, PACKAGE AIR DISCHARGE

PRESSURE

4ATT

SENSOR, PACKAGE AIR DISCHARGE

TEMPERATURE

4CTT

SENSOR, OIL COOLER OUT TEMPERATURE

6APT

TRANSDUCER, SUMP AIR PRESSURE, DRY SIDE

9APT

TRANSDUCER, REMOTE AIR PRESSURE

(OPTIONAL)

9SV

VALVE, CONDENSATE DRAIN

11SV

VALVE, ANTI-CONDENSATION SOLENOID 1

AT

AUTOTRANSFORMER (IF FITTED)

AW1

AUXILIARY WARNING 1

AW2

AUXILIARY WARNING 2

BP

BACKPLATE

C

CAPACITOR

CAB

CABINET

CDE

CONDENSATE DRAIN ERROR (OPTIONAL)

CDV

CONDENSATE DRAIN VALVE (IF FITTED)

CFO

COMMON FAULT OUTPUT

CK

CHOKE

DR

DRIVE

EB

EARTH BAR

ES

SWITCH, EMERGENCY STOP

EXC

EXTERNAL COMMUNICATIONS

F10

FUSE, EXTERNAL HEATER SUPPLY

FD

FAN DRIVE

FM

MOTOR, BLOWER

GND

GROUND

HB

HEATSINK BLOWER

HTR1

HEATER, 125 WATTS

K1

RELAY, RUN

K2

RELAY, FAULT

KM1

CONTACTOR, MAIN MOTOR

KM5

CONTACTOR, HEATSINK BLOWER

MCB1 BREAKER, MINIATURE CIRCUIT, TRANSFORMER
MCB2 BREAKER, MINIATURE CIRCUIT, CONTROL
CIRCUITS
MCB3 BREAKER, MINIATURE CIRCUIT, DR
MCB4 BREAKER, MINIATURE CIRCUIT, PSU
MCB9 BREAKER, MINIATURE CIRCUIT, HEATER
MCB10 BREAKER, MINIATURE CIRCUIT, HEATER

(EXTERNAL)

MF

MAINS FILTER (IF FITTED)

MM

MOTOR, MAIN

MMS1 BREAKER, FAN MOTOR
MMS2 BREAKER, HEATSINK BLOWER
OPT

OPTIONAL

OV

ZERO VOLTAGE

PE

PROTECTIVE EARTH

PORO POWER OUTAGE RESTART OPTION (OPTIONAL)
PSU

POWER SUPPLY UNIT

RFI

FILTER, RADIO FREQUENCY INTERFERENCE

RSP

REMOTE STOP

RST

REMOTE START

SGNe CONTROLLER, INTELLISYS
SL

SERIAL LINK

SS1-3 RELAY, SOLID STATE
ST

SERVICE TOOL

T1

TRANSFORMER, CONTROL

TH

THERMOSTAT

TRR

TRUE RUNNING

COLOR
BLK

BLACK

BLU

BLUE

BRO

BROWN

GRE

GREEN

PIN

PINK

RED

RED

SCR

SCREEN

VIO

VIOLET

WHI

WHITE

YEL

YELLOW

Wires

Numbers

Function

Wire color

1−99
100−199
200−299
300−399

Power
AC Control
DC Control
Auxiliary

Black
Red
Blue
Orange

NOTES:
1. FACTORY SUPPLIED AS SHOWN BY CONNECTION TO
OUTPUT OF CONTROL TRANSFORMER T1. WIRE NUMBER
100 & 121.
2. ALTERNATIVELY THE SUPPLY MAY BE TAKEN FROM AN
INDEPENDENT SOURCE: IN THAT CASE, FACTORY
SUPPLIED CONNECTION MUST BE DISCONNECTED.
3. ENSURE PARALLEL CONNECTION OF HEATERS.
NOTES:
1. CONNECTIONS FOR USE ON 200/230V SYSTEMS. THE
SUPPLY IS INDEPENDENT OF THE MAIN COMPRESSOR. THE
CUSTOMER MUST PROVIDE AN ISOLATOR / DISCONNECT
SWITCH ADJACENT TO THE MACHINE FOR THIS SUPPLY. IN
THAT CASE, FACTORY SUPPLIED CONNECTION MUST BE
DISCONNECTED.
2. ENSURE SERIES CONNECTION OF HEATERS.