0 general information – Ingersoll-Rand NIRVANA IRN75-160K-2S User Manual
Page 29
IRN37 - 160K - CC & IRN50 - 200H & IRN75 - 160K - 2S & IRN - 100 - 200H - 2S & IRN 250 - 300H - 2S
http://air.irco.com
27
8.0 GENERAL INFORMATION
TECHNICAL INFORMATION-SINGLE STAGE
N37K
N45K
N50H
N60H
General
Sound pressure level dB(A) *
75
75
75
75
Maximum ambient temperature ° C (° F)
46 (115)
46 (115)
46 (115)
46 (115)
Minimum ambient temperature ° C (° F)
1.7 (35)
1.7 (35)
1.7 (35)
1.7 (35)
Weight Kg (lbs)
1048 (2310)
1048 (2310)
1048 (2310)
1048 (2310)
Maximum pressure barg (psig)
10 (145)
10 (145)
10 (145)
10 (145)
Minimum pressure barg (psig)
4.5 (65)
4.5 (65)
4.5 (65)
4.5 (65)
Coolant capacity litres (US gal)
18 (4.8)
18 (4.8)
18 (4.8)
18 (4.8)
HAT switch setting ° C (° F)
120 (248)
120 (248)
120 (248)
120 (248)
Performance **
Flow at 7.5 Barg (m³/min)
6.43
7.39
−
−
Flow at 8.5 Barg (m³/min)
6.12
7.02
−
−
Flow at 10 Barg (m³/min)
5.83
6.46
−
−
Flow at 100 psig (cfm)
−
−
235
262
Flow at 125 psig (cfm)
−
−
216
248
Flow at 140 psig (cfm)
−
−
209
233
Air Cooling System
Cooling air flow m3/min (cfm)
184 (6500)
184 (6500)
184 (6500)
184 (6500)
Maximum ΔP in air ducts Pa (inch WG)
124 (0.5)
124 (0.5)
124 (0.5)
124 (0.5)
Compressed air outlet ΔT ° C (° F)
8 (15)
8 (15)
8 (15)
8 (15)
Water Cooling System
Cooling (clean) water flow l/min (US
gallon/min) @ 10 ° C (50 ° F) / 32 ° C
(90 ° F)
23/38 (6/10)
27/49 (7/13)
23/38 (6 /10)
27 /49 (7 /13)
Maximum ΔP in air ducts Pa (inch WG)
62 (0.25)
62 (0.25)
62 (0.25)
62 (0.25)
Compressed air outlet ΔT ° C (° F)
14 (25)
14 (25)
14 (25)
14 (25)
Main Power Circuit A/C (W/C) ***
Package full load current at 220V (A) **
140 (131)
168 (159)
140 (131)
168 (159)
Package full load current at 400V (A) **
75 (70 )
90 (85)
−
−
Package full load current at 460V (A) **
−
−
68 (63)
81 (77)
Package full load current at 575V (A) **
−
−
56 (52)
67 (63)
Max fuse size @ 220V (A)
250
250
250
250
Max fuse size @ 400V (A)
125
125
125
125
Max fuse size @ 460V (A)
125
125
125
125
Max fuse size @ 575V (A)
100
100
100
100
Fuse type
Fast acting class J, T or semiconductor type, current limiting interrupt
rating 200, 000 Amps RMS SYM.
Heater Circuit
110V Single Phase Rating (A)
4
4
4
4
230V Single Phase Rating (A)
4
4
4
4
Fuse type
General purpose
* In accordance with PNEUROP PN8NTC2.3
** Tolerances in accordance with ISO 1217
*** Always apply local electrical codes for sizing cables and fusing. In the absence of local codes the minimum cable
size should be calculated on basis of mean package full load current X1.25 (i.e. 25% margin)