0 general information – Ingersoll-Rand NIRVANA IRN75-160K-2S User Manual
Page 65
IRN37 - 160K - CC & IRN50 - 200H & IRN75 - 160K - 2S & IRN - 100 - 200H - 2S & IRN 250 - 300H - 2S
http://air.irco.com
63
8.0 GENERAL INFORMATION
KEY
1ATS
SWITCH, HIGH AIR END DISCHARGE
TEMPERATURE
1ATT
SENSOR, INLET TEMPERATURE
1DPS
SWITCH, FOULED OIL FILTER
1VAC
SWITCH, FOULED AIR FILTER
2APT
SENSOR, INTERSTAGE PRESSURE (2STG ONLY)
2ATT
SENSOR, AIREND DISCHARGE TEMPERATURE
2CTT
SENSOR, INJECTED COOLENT TEMPERATURE
3APT
TRANSDUCER, SUMP PRESSURE, WET SIDE
3SV
VALVE, BLOWDOWN SOLENOID
4APT
TRANSDUCER, PACKAGE AIR DISCHARGE
PRESSURE
4ATT
SENSOR, PACKAGE AIR DISCHARGE
TEMPERATURE
6APT
TRANSDUCER, SUMP AIR PRESSURE, DRY SIDE
9APT
TRANSDUCER, REMOTE AIR PRESSURE
(OPTIONAL)
9SV
VALVE, CONDENSATE DRAIN
11SV
VALVE, ANTI-CONDENSATION SOLENOID 1
AT
AUTOTRANSFORMER (IF FITTED)
AW1
AUXILIARY WARNING 1
AW2
AUXILIARY WARNING 2
BP
BACKPLATE
C
CAPACITOR
CAB
CABINET
CDE
CONDENSATE DRAIN ERROR (OPTIONAL)
CDV
CONDENSATE DRAIN VALVE (IF FITTED)
CFO
COMMON FAULT OUTPUT
CK
CHOKE
DR
DRIVE
EB
EARTH BAR
ES
SWITCH, EMERGENCY STOP
EXC
EXTERNAL COMMUNICATIONS
F10
FUSE, EXTERNAL HEATER SUPPLY
FD
FAN DRIVE
FM
MOTOR, BLOWER
GND
GROUND
HTR1
HEATER, 125 WATTS
K1
RELAY, RUN
K2
RELAY, FAULT
KM1
CONTACTOR, MAIN MOTOR
KM5
CONTACTOR, HEATSINK BLOWER
MCB1 BREAKER, MINIATURE CIRCUIT, TRANSFORMER
MCB2 BREAKER, MINIATURE CIRCUIT, CONTROL
CIRCUITS
MCB3 BREAKER, MINIATURE CIRCUIT, DR
MCB4 BREAKER, MINIATURE CIRCUIT, PSU
MCB9 BREAKER, MINIATURE CIRCUIT, HEATER
MCB10 BREAKER, MINIATURE CIRCUIT, HEATER
(EXTERNAL)
MF
MAINS FILTER
MM
MOTOR, MAIN
MMS1 BREAKER, FAN MOTOR
OPT
OPTIONAL
OV
ZERO VOLTAGE
PE
PROTECTIVE EARTH
PORO POWER OUTAGE RESTART OPTION (OPTIONAL)
PSU
POWER SUPPLY UNIT
RFI
FILTER, RADIO FREQUENCY INTERFERENCE
RSP
REMOTE STOP
RST
REMOTE START
SGNe CONTROLLER, INTELLISYS
SL
SERIAL LINK
SS1-3 RELAY, SOLID STATE
ST
SERVICE TOOL
T1
TRANSFORMER, CONTROL
TH
THERMOSTAT
TRR
TRUE RUNNING
DVF
FAN, DRIVE VENTILATION
5SV
VALVE, COOLANT STOP
COLOR
BLK
BLACK
BLU
BLUE
BRO
BROWN
GRE
GREEN
PIN
PINK
RED
RED
SCR
SCREEN
VIO
VIOLET
WHI
WHITE
YEL
YELLOW
Wires
Numbers
Function
Wire color
1−99
100−199
200−299
300−399
Power
AC Control
DC Control
Auxiliary
Black
Red
Blue
Orange
NOTES:
1. FACTORY SUPPLIED AS SHOWN BY CONNECTION TO
OUTPUT OF CONTROL TRANSFORMER T1. WIRE NUMBER
100 & 121.
2. ALTERNATIVELY THE SUPPLY MAY BE TAKEN FROM AN
INDEPENDENT SOURCE: IN THAT CASE, FACTORY
SUPPLIED CONNECTION MUST BE DISCONNECTED.
3. ENSURE PARALLEL CONNECTION OF HEATERS.
NOTES:
1. CONNECTIONS FOR USE ON 200/230V SYSTEMS. THE
SUPPLY IS INDEPENDENT OF THE MAIN COMPRESSOR. THE
CUSTOMER MUST PROVIDE AN ISOLATOR / DISCONNECT
SWITCH ADJACENT TO THE MACHINE FOR THIS SUPPLY. IN
THAT CASE, FACTORY SUPPLIED CONNECTION MUST BE
DISCONNECTED.
2. ENSURE SERIES CONNECTION OF HEATERS.