SERVICING INSTRUCTIONS

FAULT FINDING CHARTS

PILOT

WILL

NOT

STAY

LIT

OR

FIRE

GOES

OUT

IN

USE

Ensure

there

is

no

debris

around

the

pilot

assembly,

(e.g.

soot

etc.)

Check

for

fluff

in

the

pilot

aeration

hole.

See

the

Diagram

in

the

Replacing

Parts

section.

Problem

is

with

the

pipe

work

or

fittings

which

lead

to

the

fire.

Correct

and

retry.

Is

thermocouple

connection

good

in

back

of

valve?

Replace

pilot

unit.

Will

pilot

stay

alight?

Change

mag

unit.

Is

the

pilot

flame

of

the

correct

length?

Are

the

thermocouple

leads

damaged

or

loose

in

the

interrupter

block?

Is

the

ON/OF

switch

in

the

ON

(I)

position.

See

diagram

?

Change

the

pilot

unit

or

damaged

thermocouple

leads

Will

pilot

stay

alight?

With

the

pilot

running

is

the

gas

pressure

as

stated

on

the

data

badge?

With

the

fire

running

on

full

is

the

gas

at

the

pressure

stated

on

the

data

badge?

Run

for

3

mins,

turn

off,

time

interval

until

mag

unit

shuts

with

a

click.

Is

this

greater

than

7

seconds?

Run

for

3

mins,

turn

off,

time

interval

until

mag

unit

shuts

with

a

click.

Is

this

greater

than

7

seconds?

Tighten

the

connection

and

retry.

No

No

No

No

No

No

Yes

SYSTEM

O

k

Yes

Yes

Yes

Yes

No

Yes

No

Light

the

pilot

using

either

the

handset

or

the

touch

pad

FLAME

FAILURE

FUNCTI

ONAL

CHEC

k

3

IGNITION

FUNCTIONAL

CHEC

k

2

NO

SPARK

Ensure

there

is

no

debris

around

the

pilot

assembly,

(e.g.

soot

etc.)

which

could

short

the

spark,

clean

the

area.

Consult

the

users

instructions,

retry.

From

Ignition

Fault

Finding

Chart

1

Is

the

gap

between

electrode

and

thermocouple

4.0mm?

Has

ignition

lead

become

detached

or

is

connection

poor?

Remove

the

ignition

lead

from

electrode.

With

insulated

pliers.

Hold

the

tip

4.0mm

from

the

pilot

pipe

work,

is

there

a

spark

when

the

system

is

operated?

Has

the

ignition

lead

become

detached

from

the

control

box?

Replace

the

lead,

retry.

Correct

and

retry.

Check

handset

batteries

are

OK.

Replace

if

required.

Check

handset

is

on

manual.

Check

ON/OFF

switch

is

set

to

ON

(

I).

Check

batteries

to

the

control

unit.

Replace

if

required.

Retry

with

handset

and

touch

pad.

Is

the

valve

being

operated

correctly?

Yes

Yes

Yes

No

No

No

Yes

Yes

Yes

No

Replace

the

electrode

Replace

the

ignition

lead

and

retry.

No

Is

the

flue

working?

Rectify

flue

Yes

No