INSTALLATION INSTRUCTIONS

SITE REQUIREMENTS

5.2 When the appliance is installed in a masonry chimney

without a liner, there must be a minimum debris collection

area, Diagram 1b

AR2006

1b

5.3 DO NOT install onto a combustible wall; all combustible

materials must be removed from the area shown in Diagram

1c.

1c

AR1226

1160

not to
scale

400

440

960

840

100

5.4 A combustible shelf must be a minimum of 400mm above

the top of the appliance. This is based on a 150mm deep

shelf. For every extra 13mm of depth add 25mm above the

400mm from the top of the appliance, not the frame.

5.5 A side wall must be a minimum of 300mm from the side of

the appliance, not the frame.