beautypg.com

Hearth and Home Technologies GDST4336I User Manual

Page 29

background image

Heatilator • GDST4336I, GDFL4136I, GDCR4136I, GDCL4136I • 2129-900 Rev. F • 11/08

29

Figure 7.6

1. Top Vent - Horizontal Termination - (continued)

Three Elbows

V

1

Minimum

H

1

Maximum

V

2

Minimum

H

2

Maximum

V

1

+ V

2

Minimum

H

1

+ H

2

Maximum

Elbow only

2 ft.

610 mm

6 in.

152 mm

1 ft.

305 mm

6 in.

152 mm

3 ft.

914 mm

6 in.

152 mm

3 ft.

914 mm

6 in.

152 mm

2 ft.

610 mm

1 ft.

305 mm

5 ft.

1.5 m

1 ft.

305 mm

6 ft

1.8 m

1 ft.

305 mm

6 ft

1.8 m

2 ft.

610 mm

12 ft.

3.7 m

2 ft.

610 mm

11 ft.*

3.3 m

2 ft.

610 mm

10 ft.*

3 m

4 ft

1.2 m

20 ft.

6.1 m

3 ft.

914 mm

16 ft.*

4.9 m

3 ft.

914 mm

14 ft.*

4.3 m

6 ft

1.8 m

20 ft

6.1 m

*H

1

+ H

2

= 20 ft. (6.1 m) Maximum V

1

+ V

2

+ H

1

+ H

2

= 50 ft. (15.2 m) Maximum

H

2

H

1

V

2

V

1

This manual is related to the following products: