All models have clean-out
plates located inside the door
in the lower left and right
corners of the firebox. Make
sure that these are closed
when operating the unit.



WEEKLY MAINTENANCE


9 Set the stove on high fire. Open the draft to 100% and allow the stove to burn for 15 minutes.

Resume desired heat and draft setting.


9 Shut down the stove as directed in the operating instructions. Allow the stove to cool to room

temperature. Remove the small clean-out slides in the lower corners of the firebox. Tap the sides of
the burn chamber with the clean-out tool. Do not tap the firewall behind the burn box as it may
damage the insulation. Using the clean-out tool, scrape the fly ash from the clean-out chambers
toward the front of the burn chamber. Remove the fly ash
from the burn chamber and replace the clean out chamber
doors.



9 Remove the ash pan and dump the ash into a metal container.


9 Remove the firepot by stopping the fuel stirrer in the upright position, slide the collar off of the fuel

stirrer coupler shaft and pull up and out on the firepot. Using the clean-out tool, remove any ash that
might have built up in the system or air intake.

3502 models make sure that the
ash pan is locked in place.

All models have a heat exchanger
tube cleaning rod to clean the heat
exchanger tubes. This should be
done twice a day if you are using
wet or dirty fuel.






3500P & 3500L models have (2)
front cleanout slides that must be
in the closed position when
burning the unit.

Must be positioned as shown to
remove firepot

Coupler Shaft

Ash pan

This manual is related to the following products: