Clearances to combustibles – Hearth and Home Technologies 3500P User Manual
Page 10
CLEARANCES TO COMBUSTIBLES
The stove must be installed with the following minimum clearances to side and back wall combustible
materials. NOTE: These are minimum clearances to combustible walls established by the testing lab.
The amount of room needed on the left side of the unit to access the electrical panel is (6) six inches.
When venting straight out the back of the unit, the B clearance is 1”. C clearance is for a vertical vent
install.
10
A
B
C
D
E
E
A=1” B=7” or 1”
if straight out the
wall install
C=3” if tee install
D=3” E=1”
Residential/Mobile Home
Residential/ Mobile Home
Horizontal + Vertical
Vertical Installation
Corner Installation
28”
6”
min.
HEARTH PROTECTION
The side and top clearance are to be used when
installing the CountrySide into an alcove as shown to
the left and below.
Top View
The 14” clearance above the back
lid is only for clearance to open
the lid. If you are using the front
lid this clearance is 1”
30”
14”