beautypg.com

Clearances to combustibles – Hearth and Home Technologies 3500P User Manual

Page 10

background image

CLEARANCES TO COMBUSTIBLES


The stove must be installed with the following minimum clearances to side and back wall combustible
materials. NOTE: These are minimum clearances to combustible walls established by the testing lab.
The amount of room needed on the left side of the unit to access the electrical panel is (6) six inches.
When venting straight out the back of the unit, the B clearance is 1”. C clearance is for a vertical vent
install.

10










































A

B

C

D

E

E

A=1” B=7” or 1”
if straight out the
wall install
C=3” if tee install
D=3” E=1”

Residential/Mobile Home

Residential/ Mobile Home

Horizontal + Vertical

Vertical Installation

Corner Installation

28”

6”
min.

HEARTH PROTECTION

The side and top clearance are to be used when

installing the CountrySide into an alcove as shown to

the left and below.

Top View

The 14” clearance above the back

lid is only for clearance to open

the lid. If you are using the front

lid this clearance is 1”

30”

14”

This manual is related to the following products: