INSTALLATION CONFIGURATIONS

The MagnuM Countryside Biomass Corn/Pellet Stove / Fireplace Insert may be installed as follows:
1) A freestanding unit 3500P & 3500L models
2) A hearth mounted fireplace insert into a masonry or factory built fireplace (3502 & 3500L)
3) A built-in heater mounted in an alcove with a pedestal (3500P & 3500L)
4) A built-in heater mounted on a non-combustible floor without a pedestal (3502 & 3500L)

MOBILE HOME INSTALLATION REQUIREMENTS

IN ADDITION TO THE STANDARD INSTALLATION INSTRUCTION, THE FOLLOWING

REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:


WARNING

DO NOT INSTALL IN SLEEPING ROOM



1) Stove must be permanently bolted to the floor.
2) Stove must have permanent outside air source.
3) Stove must be permanently electrically ground to the steel chassis of the mobile home.
4) All vertical chimney vent must have wall supports every (5) five feet.
5) All exhaust systems must have a spark arrestor.

CAUTION

The structural integrity of the mobile home floor, wall and ceiling must be maintained.

Check with your local building official as other codes may apply.