Hearth and Home Technologies 3500P User Manual
Magnum countryside, Owner’s manual, Biomass corn/wood pellet stove /fireplace insert
MAGNUM COUNTRYSIDE
®
BIOMASS CORN/WOOD PELLET STOVE /FIREPLACE INSERT
Safety tested and EPA exemption tested by Omni-Test Laboratories, Inc to UL 1482, CAN/ULC-S627, ULC-S628,
APFI requirements, Oregon administrative rules 814-23-900 to 814-23-909 and E.P.A. Method 28A.
OWNER’S MANUAL
Installation – Operation – Maintenance Instructions
NOTE: These instructions must be saved
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS BIOMASS CORN/
WOOD PELLET BURNING STOVE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
IMPORTANT: Always contact your local dealer/installer with questions before contacting the factory.
When you call have your serial number, purchase date, who installed the unit and a list of questions.
This appliance must be installed by a qualified/trained factory approved installer to assure proper operation/warranty.
9 When installing your Countryside Biomass Corn/Pellet stove, particular attention needs to be made in
regards to fire protection. If the unit is not properly installed, a house fire may result. For your safety,
follow the installation and operation instructions provided, and if a question arises contact local building or
fire officials about restrictions and installation requirements in your area.
9 Read the operations and fuel section of this manual before plugging in your unit.
9 Always unplug the unit before attempting any service work.
9 Do not connect the unit to a chimney flue already serving another appliance.
9 When installing the chimney pipe to the unit, it is important to remember that the unit operates on a
negative pressure and the chimney on a positive pressure. All chimney connections, elbows and fittings
must be airtight. (proper venting practices must be followed. Consult with a venting professional)
9 Ashes must be disposed of in a metal container with a tight fitting lid.
9 All minimum clearances to combustibles must be followed.
9 The Countryside Biomass Corn/Pellet Stove is tested for operation with 14% or less moisture corn or
with wood pellets with an ash content of no more than 3%. It is recommended that Corn with 11-12%
moisture or wood pellets with an ash content of 1% or less be used for efficient operation of this unit.
Corn over 12% moisture has a lower BTU value and will be hard to burn on the lower settings.
9 It is important to use fuel that is clean, dry and consistent. Make sure that your supplier is giving you
the same fuel each time that you purchase. It is recommended that you purchase your entire heating season
supply of fuel at one time so that the fuel will be the same.
9 A voltage surge protector or ground fault outlet is required for this unit. The electrical warranty
will be voided if surge protection is not installed before operating this unit.
9 A grounded outlet must be provided with proper polarity. A constant 115 volt, 60 cycles must be
provided for proper operation or the warranty of this appliance will be forfeited.
9 DISCLAIMER NOTICE: No guarantee is made regarding the heating capacity of this product. The actual
area that this unit will heat depends on factors such as building conditions, heat loss, type of construction,
amount and type of insulation, type of air movement and heat distribution and the location of the product.
9 IMPORTANT: Your home must be checked to verify that there is no negative pressure that will effect the
operation of this appliance.
AMERICAN ENERGY SYSTEMS, INC. GRANTS NO WARRANTY, IMPLIED OR STATED, FOR THE
INSTALLATION OR MAINTENANCE OF THE STOVE AND ASSUMES NO RESPONSIBILITY FOR ANY
CONSEQUENTIAL DAMAGE(S).
AMERICAN ENERGY SYSTEMS, INC. -150 Michigan Street SE - HUTCHINSON, MINNESOTA 55350
Web Site:
Rev. date 08/06
Document Outline
- TABLE OF CONTENTS
- SHELLED CORN (11-12 percent moisture recommended)
- When you receive your MagnuM Countryside Corn/Pellet Stove, Leg unit or Fireplace Insert, be careful to inspect all parts and components to make sure that nothing was damaged or lost in shipment. If there was shipping damage, be sure to report it to your Countryside reseller, or the shipping company that delivered your unit. Freight damage claims must be made to the Freight Company immediately. If parts are missing contact your local MagnuM Countryside dealer or contact the factory right away. Your satisfaction is our top priority.
- MAGNUM COUNTRY SIDE REPLACEMENT PARTS LIST
- ORDER #
- DESCRIPTION
- MF3511
- Bronze Bushing (fuel stirrer shaft bearing) 2 pcs. (all countryside models)
- MF3512
- Draft Slide / Electrical control access Knob
- MF3513
- Fuel Stirrer (for Firepot)
- MF3514
- Fuel Stirrer driver shaft assembly
- MF3515
- Complete 24K Door Assembly (when purchased separate from unit)
- MF3516
- Fuel Stirrer Chain (specify unit model, serial number and age)
- MF3517
- Fuel Stirrer Sprocket (11-tooth sprocket on motor, 3/8” Diameter shaft)
- MF3518
- Fuel Stirrer Sprocket (11-tooth sprocket on shaft, ½” Diameter shaft)
- MF3519
- Complete Nickel Door Assembly (when purchased separate from unit)
- MF3521
- Firepot Scraper assembly (all models)
- MF3522
- Complete Black Door assembly (glass, handle, air-wash) (when purchased separate from unit)
- MF3522-CR
- Return credit for MF3522 door when traded in for another door finish or for credit
- MF3523
- Door Handle assembly (all models)
- MF3524
- Black Air-Deflector kit (Complete Assembly) (when purchased separate from unit)
- MF3526
- Door Latch shoulder bolt with ¼-20 nut
- MF3527
- Door Hinge (each) takes two (2) per unit
- MF3530
- 1 ½” Corn Feed Auger (3500P, 3500L, 3502 models)
- MF3531
- Door Glass (all models of Countryside & 7500 Corn Furnace)
- MF3535
- Stainless Steel Firepot (for 7500 Furnace models & older Countryside models)
- MF3535-B
- Stainless Steel Firepot (for all Countryside models)
- MF3536
- Auger Safety Switch
- MF3537
- Low limit / Fan Safety sensor 110 deg.
- MF3538
- Hi-Temp safety sensor 250 deg.
- MF3540
- Fuel Stirrer Motor (all models)
- MF3541
- Room Air Fan (when purchased separate from unit)
- MF3542
- Draft Blower (all models) when purchased separate from unit
- MF3549
- Fireplace Insert Shroud (when ordered separate from unit)
- P7550
- 3500P Brick Board
- MF3570
- Gold Air-Deflector kit (Complete Assembly) (when purchased separate from unit)
- MF3571
- Nickel Air Deflector kit (Complete Assembly) (when purchased separate from unit)
- MF3573
- Auger Feed Motor (all models with 1 ½” dia. Feed auger)
- MF3577
- Auger Coupler
- MF3578
- Auger Motor Gasket
- MF3592
- Millivolt Thermostats
- MF3593
- Circuit Board, Ortech (current board used on Countryside)
- MF3598
- 24K Gold Queen Ann Leg Set – 4 legs & plating (when purchased separate from unit)
- MF3599
- Nickel Queen Ann Leg Set – 4 legs & plating (when purchased separate from unit)
- MF3600
- Black Queen Ann Leg Set – 4 legs & painting (when purchased separate from unit)
- MF3601
- Ash Pan Weldment, Pedestal
- MF3609
- Installation Hardware Packet
- MF3610
- Exhaust Draft Motor Gasket (all models)
- MF3611-L
- Ash Pan for Countryside Leg Unit
- P003213
- Back Lid Assembly
- P003214
- Front Lid Assembly
- P003015
- Clean Out Slides
- P003051
- Mounting Bracket, Air Deflector
- P003053
- #8 x ½” Tek Screw ¼” Hex
- P003054
- #10-32 x 3/8” Philips Screw
- P003055
- Air Deflector Nut
- P003067
- Clean Out Rod
- P003073
- Clean-out Door
- P003080
- Rod (Hinge & Hopper Switch)
- ORDER #
- DESCRIPTION
- P6092
- Fuel stirrer retaining collar
- P003088
- ½” ID Shaft Collar
- P003099
- Auger Motor Bolt (#10-32 x 1” Hex)
- P003147
- Vibration Washers
- P003148
- #10 Washer
- P003156
- Spring Latch for Blower
- P003198
- Exhaust Tube
- P003201-W
- Exhaust Slider Weldment
- P003203
- Slider Knob (Exhaust & Circuit Board Access Door)
- P003222
- Access Door Magnetic Tape
- P003230
- Cord Connector
- P003231
- Cord
- P003232
- Wire Harness Assembly
- P003252
- Top Hinge Pin
- P003253
- Bottom Hinge Pin
- P003255
- Glass Seal Gasket
- P003257
- Glass Clips
- P7714
- Draft Slide Gate
- RP2094
- 2” Finishing Plug for Magnum Countryside Unit
- R-137
- ½” Graphite Door Seal Gasketing (priced per foot) Magnum Countryside Door
- Discontinued Countryside Parts (available for older models)
- MF3510
- Air Wash Kit (includes gasket) specify unit model, serial number (for older model countryside units)
- MF3520
- Feed Auger for J3500 1” dia. auger tube
- MF3528
- Ash Pan assembly (J3500 model) not to be used for 3500P, 3502, 3500L models
- MF3574
- Ash Pan latch assembly (J3500 model)
- MF3529
- Front Ash Pan cover (J3500 model)
- MF3532
- Power Cord (hard wired cord for older Countryside models J3500)
- MF3533
- Fan Speed Control (for models with Y1802-4 circuit board)
- MF3534
- Fuel Stirrer on/off switch (for models with Y1802-4 circuit board)
- MF3539
- Auger Feed Motor 3M-103 (J3500 models with 1” dia. Feed auger)
- CF26
- Auger Feed Motor 8 rpm (J3500 model, 3500P models with 1” dia. Feed auger) (formerly MF3572)
- MF3541-C
- Room-Air Fan (4C-447 Optional larger capacity blower) when purchased separate from unit
- MF3543
- Circuit Board retro-fit kit for older model J3500 units (from Y1802-4 to Ortech circuit board)
- MF3544
- Brick Board J3500 (for units with 1” dia. Auger (Until stock is gone, then use MF3550)
- MF3545
- Brick Board (7500 Corn Furnace) (for earlier units with 13 ½” wide Brick Board)
- MF3546
- Fuel Stirrer control board kit (for models with Y1802-4 circuit boards)
- MF3597
- Firepot Fuel Spreader w/ Bolt & Nut (used on units with replaceable fuel spreader)
- MF3612
- Combustion Enhancement System for all Model Countryside