B–4

User Memory and the Stack

File name 32sii-Manual-E-0424
Printed Date : 2003/4/24 Size : 17.7 x 25.2 cm

1. Press and hold down the

†

key.

2. Press and hold down

<

.

3. Press

6

. (You will be pressing three keys simultaneously). When you

release all three keys, the display shows

&

if the operation

is successful.

Category CLEAR

ALL

MEMORY

CLEAR

(Default)

Angular mode

Unchanged

Degrees

Base mode

Unchanged

Decimal

Contrast setting

Unchanged

Medium

Decimal point

Unchanged

"

)

"

Denominator (/c value) Unchanged

4095

Display format

Unchanged

FIX 4

Flags Unchanged

Cleared

Fraction–display mode Unchanged

Off

Random–number seed Unchanged

Zero

Equation pointer

EQN LIST TOP

EQN LIST TOP

Equation list

Cleared

Cleared

FN = label

Null

Null

Program pointer

PRGM TOP

PRGM TOP

Program memory

Cleared

Cleared

Stack lift

Enabled Enabled

Stack registers

Cleared to zero

Cleared to zero

Variables

Cleared to zero

Cleared to zero

Memory may inadvertently be cleared if the calculator is dropped or if power
is interrupted.

The Status of Stack Lift

The four stack registers are always present, and the stack always has a
stack–lift status. That is to say, the stack lift is always enabled or disabled
regarding its behavior when the next number is placed in the X–register.
(Refer to chapter 2, "The Automatic Memory Stack.")