Installer setup tables – Honeywell PRESTIGE THX9000 User Manual
Page 13

13
69-2057EFS—03
Installer setup tables
Setup functions
(factory default setting listed, other options available)
393
Away mode high temp. setting
85° F (29.5° C)
394
Away mode dehumidification
65% relative humidity
400
Ventilation Control
Off
401
Number of Bedrooms
2
402
Total Sq. Ft. of Home
1000
403
Ventilation CFM
160
404
Max Ventilation Percentage Limit
50%
405
Ventilation Fan Action
Ventilation Forces Fan On
406
Ventilation in High Humidity
On
431
Ventilation Lockout High Temperature
None
432
Ventilation Lockout Low Temperature
None
500
Reminder: Furnace filter
Off
502
Furnace filter runtime counter
Count heat and cool
510
Reminder: Humidifier pad
Off
520
Reminder: UV bulb
Off
525
Installer Custom Reminders
Add Customer Reminder
530
Adaptive Intelligent Recovery
On
540
Number of schedule periods
4
580
Minimum compressor off time
5 minutes
600
Maximum heat range
90° F (32° C)
610
Minimum cool range
60° F (15.5° C)
640
Clock format
12-hour
650
Extended fan on time (heat)
Off
660
Extended fan on time (cool)
Off
670
Keypad lock
Unlocked
680
Temp. control (heat)
Standard
690
Temp. control (cool)
Standard
700
Temperature display offset
No offset
701
Humidity display offset
No offset
710
RESTORE FACTORY DEFAULTS
No: Advanced Options
Customer contact information
(optional, but recommended)
1100
Dealer name
Your company name
1150
Dealer phone number
Your telephone contact
1200
Dealer email address
Your email address
1250
Dealer website
Your web site
1300
Dealer Message
Edit
1400
Configurable U1 Relay
None
1405
Configurable U2 Relay
None
1500
Low Speed Fan Position
Normally Closed
Note: All installer options, including Dealer name, contact information and message can be