Getting started – Hearth and Home Technologies Santa Fe Pellet Insert SANTAFEI-B User Manual

Page 5

background image

R

September 1, 2008

7019-205C

Page 5

Santa Fe Pellet Insert

2

Getting Started

A. Design, Installation & Location Considerations

Damaged parts could impair safe

operation. Do NOT install damaged, incomplete or substitute
components.

1. Appliance Location

OT

Check building codes prior to installation.

• Installation MUST comply with local, regional, state and

national codes and regulations.

• Consult insurance carrier, local building inspector, fire

officials or authorities having jurisdiction over restrictions,
installation inspection and permits.

It is a good idea to plan your installation on paper, using
exact measurements for clearances and floor protection,
before actually beginning the installation

Consideration must be given to:

• Safety, convenience, traffic flow

• Placement of the chimney and chimney connector.

• If you are not using an existing chimney, place the appli-

ance where there will be a clear passage for a factory-
built listed chimney through the ceiling and roof.

• Installing an optional outside air kit would affect the loca-

tion of the vent termination.

T O

If burning shelled field corn, you must use ap-

proved venting specifically designed for corn to prevent corro-
sion or degradation. Follow the instructions from the venting
manufacturer.

Since pellet exhaust can contain ash, soot or sparks, you
must consider the location of:

• Windows

• Air

Intakes

• Air

Conditioner

• Overhang, soffits, porch roofs, adjacent walls

• Landscaping,

vegetation

When locating vent and venting termination, vent above
roof line when possible.

Marginal Location:

Below peak

Location NOT recommended:

Not the highest point of the roof
Wind loading possible

Multi-level Roofs

Windward

Leeward

Recommended:
Outside Air Intake
on windward side

NOT recommended:
Outside Air Intake
on leeward side

Recommended Location:

Above peak

Recommended:

Insulated exterior chase

in cooler climates

Recommended Location:

Above peak
Inside heated space

Location NOT recommended:

Too close to tree
Below ad acent structure
Lower roof line
Avoid outside wall

Marginal Location:

Wind loading possible

OT

Locating the appliance in a location of

considerable air movement can cause intermittent smoke
spillage from appliance. Do not locate appliance near:

Frequently open doors

Central heat outlets or returns

Figure 5.1