Appliance set-up, Caution – Hearth and Home Technologies Santa Fe Pellet Insert SANTAFEI-B User Manual

Page 17

background image

R

September 1, 2008

7019-205C

Page 17

Santa Fe Pellet Insert

7

Appliance Set-Up

A. Leveling System

B. Outside Air Kit Instructions

Parts Included in Kit: 1 piece of 2 inch x 3 ft. flex hose,
2 hose clamps, 1 collar assembly, 1 termination cap
assembly, 1 trim ring, fasteners.

1. Measure distance from floor to air vent opening in appli-

ance and mark location on wall.

2. Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch

(64-76mm) opening on inside wall and a 3 to 3-1/2 inch
(76-89mm) opening on outside of house.

3. Use hose clamp to secure flex pipe to collar assembly.

4. Slide trim ring over flex pipe and run pipe through wall.

5. Attach hose to outside termination cap with second

hose clamp.

6. Secure termination cap to outside surface.

7. Secure trim ring to interior wall.

Tools Needed: Phillips head screwdriver; wire cutters;
hole saw or jig saw.

CAUTION

Never draw outside combustion air from:
• Wall, floor or ceiling cavity
• Enclosed space such as an attic or garage

The leveling bolts are located at the rear of the appliance.
To access the bolts, remove the front access panels. Reach
in and turn the bolt to the desired height to level the appli-
ance.

Figure 17.1

Leveling Bolt on Each Side

Flex Hose

Hose Clamp

Collar
Assembly

Hose Clamp

Trim Ring

Termination
Cap Assembly

Air Intake Channel

Figure 17.2