beautypg.com

Santa fe pellet insert – Hearth and Home Technologies Santa Fe Pellet Insert SANTAFEI-B User Manual

Page 40

background image

Page 40

7019-205C

September 1, 2008

R

Santa Fe Pellet Insert

16. Snap Disc #1 (Convection Blower) 110°F

Snap disc #1 is located on the right side of the firebox. There
are 2 purple wires connected to it. This snap disc turns the
convection blower on and off as needed. Power is always
present at snap disc #1.

17. Snap Disc #2 (Fuel Delivery Interrupt) 250°F

Snap disc #2 is located on the back side of the feed drop tube.
(see Figure 41.2 on page 41). There is 1 orange wire and 1
black wire connected to it. This snap disc will turn off the feed
system, which will turn off the appliance if an overfire condition
should occur or if the convection blower should fail to operate.
If this occurs the snap disc with automatically reset itself.

18. Snap Disc #3 (Burn Back Protector) 250°F

Snap disc #3 is mounted on the back of the auger tube in the
center of the appliance and has a reset button. To access
it remove the right side panel. If the fire tries to burn back
into the feed system or push exhaust up the feed tube, this
snap disc will shut the entire system off. This disc must be
manually reset.

Thermocouple

Burn

Selector

Thermostat

Block

Female

Male

Igniter

Call

Light

Snap

Disc #3

Reset

Button

Fuse

Receptacle

Snap

Disc #1

Exhaust
Blower

Convection

Blower

Vacuum

Switch

Snap

Disc #2

Capacitor

Feed

Motor

Yellow

Y

ellow

Y

ellow

Blue

Blue

Gray

Gray

Black

Black

Black

Black

Black

White

White

Red

Red

Purple

Red

White

19. Vacuum Switch

The vacuum switch is located on the lower left side of the
appliance behind left access panel. This switch turns the
feed system on when vacuum is present in the firebox. The
vacuum switch is a safety device to shut off the feed motor if
the exhaust or the heat exchanger system is dirty or plugged
or if the firebox door is open.

20. Wiring Harnes

See Figure 40.1 below

Figure 40.1