beautypg.com

Arning – Hearth and Home Technologies Santa Fe Pellet Insert SANTAFEI-B User Manual

Page 34

background image

Page 34

7019-205C

September 1, 2008

R

Santa Fe Pellet Insert

Figure 35.3

Ash Build Up in Firebox

Pellets Back Up
In Feed Tube

Firepot Overfills

Tall, Lazy Flame, Orange in Color

Incorrect

Correct Flame Size, Yellow/White in Color

Correct

Figure 34.1

Figure 34.2

Figure 34.3

Fire Risk.

ARNING

High ash fuels, or lack of maintenance,
can cause the repot to ll with ash
and clinker. If the repot lls to the top,
immediately shut down the unit and clean.

Failure to do so could result in smoking,
sooting and possible hopper res.

D. High Ash Fuel Content Maintenance

Frequency: When the ash build-up exceeds more

than half way up the firepot.

By: Homeowner

Poor quality pellet fuel, or lack of maintenance, can create
conditions that make the firepot fill quickly with ashes and
clinkers.

This condition makes the appliance susceptible to overfill-
ing the firepot with pellets which may result in smoking,
sooting and possible hopper fires. Figure 34.1 shows an
example where the firepot overfills, pellets back up into the
feed tube and ash has accumulated in the firebox.

An inefficient and non-economical method of burning of
fuel caused by poor quality pellet fuel

is shown in

Figure

34.2.

The correct flame size when good quality, premium pellet
fuel is burned is shown in Figure 34.3.

If the ash buildup exceeds the half way point in the firepot
IMMEDIATE ATTENTION AND CLEANING IS REQUIRED.