Lower range, Upper range – Humminbird Matrix 531338-1_A User Manual
Page 18
30
Lower Range
(2D Sonar, 2D Zoom, 2D Big Digits Views Only)
Lower Range sets the deepest depth range that will be displayed, and is only available on
the X-Press™ Menu when you are in the 2D Sonar, 2D Zoom, or 2D Big Digits Views.
Automatic is the default setting. When in automatic mode, the lower range will be
adjusted by the unit to follow the bottom. Selecting a specific setting locks the depth
range into Manual mode. Use both Upper and Lower Range together to view a specific
depth range manually when looking for fish or bottom structure.
will be displayed
in the lower right corner of the screen when you start manually adjusting the Lower
Range to indicate that you are in Manual mode.
NOTE: A minimum distance of 10 feet will be maintained between the Upper and Lower Range
regardless of the manual settings entered.
To adjust the Lower Range:
1. Highlight Lower Range on the Sonar X-Press™ Menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to increase or decrease the Lower
Range setting. (AUTO, 10 to 1000 feet, 3 to 330 meters [International Models Only],
Default = AUTO)
For example, if you are fishing in 60 feet of water but are only interested in the first 30
feet (surface to a depth of 30 feet) you should set the Lower Depth Range limit to 30.
The display will show the 0 to 30 foot range, allowing you to see a more detailed view
than you would see if the display went all the way to the bottom.
M
29
Upper Range
(Advanced: 2D Sonar, 2D Big Digits Views Only)
Upper Range sets the shallowest depth range that will be displayed. The Upper Range menu
choice is available when User Mode is set to Advanced (see Setup Menu Tab: User Mode) and
is only available on the X-Press™ Menu when you are in the 2D Sonar or 2D Big Digits Views.
Upper Range is often used with Lower Range.
NOTE: A minimum distance of 10 feet will be maintained between the Upper and Lower Range
regardless of the manual settings entered.
To adjust the Upper Range:
1. Make sure you are in Advanced Mode, then highlight Upper Range on the Sonar X-
Press™ Menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to increase or decrease the Upper
Range setting. (0 to 990 feet or 0 to 327 meters [International Models Only], Default
= 0)
For example, if you are only interested in the area between 20 and 50 feet deep, you
should set the Upper Depth Range to 20 and the Lower Depth Range to 50. The 2D
Sonar View will then show the 30 foot area between 20 and 50, and will not show the
surface or the bottom (assuming the bottom is deeper than 50 feet), and will show
greater detail for that area between 20 and 50 feet.
M47_Man_Eng_531338-1_A.qxd 12/13/2004 12:36 PM Page 34