e) Harvest Cycle

Same as the initial harvest cycle. See "II.B.1.b) Initial Harvest Cycle."

Note: Unit continues to cycle until BC is satisfied or power is turned off. The unit always

restarts at the 1-minute fill cycle.

f) Shutdown

When ice contacts the thermostatic bulb (BC switch open), BC shuts down the unit within
10 seconds. BC is factory set, and generally no adjustment is required. However,
adjustment may be needed in some conditions, particularly at higher altitude
locations.

CAUTION! Do not adjust S4 dip switch 7 out of the factory default

position on this model. This dip switch must be left in the factory default position
or this unit will not operate correctly.

Legend:

BC–bin control; CB–control board; Comp–compressor; FMR–fan

motor-remote;

F/S–float switch; HGV–hot gas valve; LLV–liquid line valve;

PM–pump motor; WV–inlet water valve