beautypg.com

Hoshizaki KM-2500SWH3 User Manual

Page 61

background image

61

2. Drain the water tank:

1) Turn off the power supply, then remove the front panel. Move the control switch to the

"OFF" position.

2) Remove the insulation panel. Remove the cap located on the front bottom part of the ice

dropping hole. Drain the water tank. See Fig. 7.

3) Replace the cap and the insulation panel in their correct positions. Be careful not to

cross thread the cap.

4) Replace the front panel in its correct position.
5) Remove all ice from the storage bin. Clean the storage bin using a neutral cleaner.

Rinse thoroughly after cleaning.

3. On water-cooled model only, first remove the water from the water-cooled condenser:

1) Make sure the power supply is off, then remove the front panel and right side panel.
2) Close the condenser water supply line shut-off valve. If connected to a closed loop water

supply, also close the condenser return line shut-off valve.

3) Open the condenser water supply line drain valve. If connected to a closed loop water

supply, also open the condenser return line drain valve.

4) Attach a compressed air or carbon dioxide supply to the condenser water supply line

drain valve.

5) Open the water regulating valve by using a screwdriver to pry up on the spring retainer

underneath the spring. While holding the valve open, blow out the condenser using the
compressed air or carbon dioxide supply until water stops coming out.

6) Close the drain valve(s), then replace the right side panel and front panel in their correct

positions.

Fig. 7

Cube Guide

Separator

Front

Cap

Inside of Ice
Dropping Hole

This manual is related to the following products: