Dcm-750bwh – Hoshizaki CUBELET ICEMAKER/DISPENSER DCM-750BAH-OS User Manual
Page 7
7
Note: We reserve the right to make changes in specifications and design without prior
notice.
3. DCM-750BWH
AC SUPPLY VOLTAGE
115/60/1
COMPRESSOR
120 V
13.2 RLA
60 LRA
GEAR MOTOR
120 V
3 FLA
1/4 HP
AGITATING MOTOR
120 V
1.8 FLA (Total)
110 W
DISPENSING MOTOR
120 V
0.9 FLA
55 W
OTHER
120 V
0.6 A
MAXIMUM FUSE SIZE
20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIRC. BREAKER (CANADA ONLY)
20 A
MINIMUM CIRCUIT AMPACITY
20 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
* 744 (337) 719 (326) 708 (321)
Reference without *marks
80
696 (316) 684 (310) 673 (305)
90
662 (300) * 654 (297) 640 (291)
100
630 (286) 620 (281) * 573 (260)
SHAPE OF ICE
Cubelet (Compressed Flake Ice)
ICE QUALITY
Approx. 90%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
95 lbs.
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1383 (5.1)
1410 (4.5)
POTABLE WATER
89 (12)
78 (12)
WATER-COOLED CONDENSER
606 (81.4)
325 (49.7)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
34-1/16" x 28-1/2" x 48-1/16" (865 x 723 x 1221 mm)
EXTERIOR FINISH
Stainless Steel; Galvanized Steel (Rear)
WEIGHT
Net 375 lbs. ( 170 kg ), Shipping 405 lbs. ( 184 kg )
CONNECTIONS - ELECTRIC
Permanent Connection
- WATER SUPPLY
Inlet 1/2" FPT
Condenser Inlet 1/2" FPT
- DRAIN
Drain Pan 3/4" FPT
Condenser Outlet 1/2" FPT
Bin Drain 3/4" FPT
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 1/4 HP Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
Water Regulating Valve
BIN CONTROL SYSTEM
Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR
Hermetic, Model RS55C2E-CAA-219
CONDENSER
Air-cooled, Fin and tube type
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A,
1 lb. 2.7 oz. (530 g)
DESIGN PRESSURE
High 460 PSIG, Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-off Relay
COMPRESSOR PROTECTION
Auto-reset Overload Protector
GEAR MOTOR PROTECTION
Manual reset Circuit Breaker
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch and Timer
ACCESSORIES - SUPPLIED
Spare Fuse
- REQUIRED
Legs
OPERATING CONDITIONS
VOLTAGE RANGE
104 - 127 V
AMBIENT TEMP.
45 - 100° F
WATER SUPPLY TEMP.
45 - 90° F
WATER SUPPLY PRESSURE
10 - 113 PSIG
ENG F-013.0.1196