D. sequence of electrical circuit – dispensing, Continuous dispense – Hoshizaki CUBELET ICEMAKER/DISPENSER DCM-750BAH-OS User Manual
Page 32
3
D. Sequence of Electrical Circuit – Dispensing
1. Continuous Dispense
Agitating motor energizes for .6 seconds for every seconds of accumulative dispense
time. Maximum dispense time per dispense switch activation is 60 seconds. After
60 seconds, the dispense switch must be disengaged and engaged again.
BK
BLACK
O
ORANGE
W/BK WHITE/BLACK
BR
BROWN
P
PINK
W/BR WHITE/BROWN
BU
BLUE
R
RED
W/BU WHITE/BLUE
DBU DARK BLUE
V
VIOLET
W/O WHITE/ORANGE
GY
GRAY
W
WHITE
W/R WHITE/RED
LBU LIGHT BLUE
Y
YELLOW
WIRE COLOR CODE
DCM-750BAH-OS,
DCM-750BWH-OS
DCM-750BAH,
DCM-750BWH