beautypg.com

Techspecs, Quickspecs, Proliant bl30p – HP BL30p User Manual

Page 30: Proliant bl30p techspecs

background image

ProLiant BL p-Class

ProLiant BL p-Class

ProLiant BL p-Class

ProLiant BL p-Class
Server Blade Enclosure

Server Blade Enclosure

Server Blade Enclosure

Server Blade Enclosure
with enhanced backplane

with enhanced backplane

with enhanced backplane

with enhanced backplane
components

components

components

components

Dimensions

Dimensions

Dimensions

Dimensions

Height

10.5 in (26.67 cm)

Width

17.60 in (44.70 cm)

Depth

28.86 in (73.30 cm)

Input Specifications

Input Specifications

Input Specifications

Input Specifications

Rated input voltage

-43 VDC to -53 VDC

Nominal -48 VDC

Rated input current

125 A at -48 VDC

Rated input Power

6000 W

Individual Server Blade

Individual Server Blade

Individual Server Blade

Individual Server Blade
Bay Ratings

Bay Ratings

Bay Ratings

Bay Ratings

Rated input voltage

-43 VDC to -53 VDC

Nominal -48 VDC

Rated input current

14.6 A at -48 VDC

Rated input Power

700 W

Temperature Range

Temperature Range

Temperature Range

Temperature Range

Operating

50° to 95° F (10° to 35° C)

Non-Operating

-22° to 140° F (-30° to 60° C)

Relative Humidity

Relative Humidity

Relative Humidity

Relative Humidity
(non-condensing)

(non-condensing)

(non-condensing)

(non-condensing)

Operating

20% to 80%

Non-Operating

5% to 95%

Wet Bulb Temperature

Wet Bulb Temperature

Wet Bulb Temperature

Wet Bulb Temperature

Operating

82.4° F (28° C)

Non-Operating

101.7° F (38.7° C)

NOTE:

NOTE:

NOTE:

NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa.

Operating and

Operating and

Operating and

Operating and
Performance

Performance

Performance

Performance
Specifications for

Specifications for

Specifications for

Specifications for
ProLiant BLp-Class RJ-45

ProLiant BLp-Class RJ-45

ProLiant BLp-Class RJ-45

ProLiant BLp-Class RJ-45
Patch Panel 2 with Fiber

Patch Panel 2 with Fiber

Patch Panel 2 with Fiber

Patch Panel 2 with Fiber
Channel pass through

Channel pass through

Channel pass through

Channel pass through

Dimensions

Dimensions

Dimensions

Dimensions

Height

10.405 in (26.43 cm)

Width

1.535 in (3.899 cm)

Depth

27.697 in (70.35 cm)

Capability

Capability

Capability

Capability

IEEE 802.2, 802.3, 802.3u

Network Transfer Rate

Network Transfer Rate

Network Transfer Rate

Network Transfer Rate

10 Base-T (half-duplex)

10 Mbps

10 Base-T (full-duplex)

20 Mbps

100 Base-TX (half-duplex)

100 Mbps

100 Base-TX (full-duplex)

200 Mbps

1000 Base-TX (full-duplex)

1000 Mbps

Fiber Channel SAN

Fiber Channel SAN

Fiber Channel SAN

Fiber Channel SAN

Velio VC1070 re-timer

Auto-rate negotiate between 2G and 1G

Connector

Connector

Connector

Connector

Network

32 RJ-45 in the back.

Fiber Channel SAN

16 Pluggable SFP optical cages in the front

Cable Support

Cable Support

Cable Support

Cable Support

10 Base-TX

Categories 3, 4, or 5 UTP (2 or 4 pair);
up to 328 ft (100 m)

100 Base-TX

Category 5 UTP (2 pair); up to 328 ft/100 m

1000 Base-TX

Category 5E (4 pair); up to 328 ft (100 m)

Fiber Channel

SFP optical cable

EMI

EMI

EMI

EMI

FCC Class A

ICES-003 Class A

AS/NZS 3548 Class A

VCCI Class A

NOTE:

NOTE:

NOTE:

NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper
operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or
30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude
maximum for storage is 70 KPa.