Test power supply resistance – HP GRACO OR PRO TI1681A User Manual
Page 31

Electrical Tests
309293J
31
Test Power Supply Resistance
1.
Prepare the gun for service as instructed on page
41.
2.
Remove the power supply (18), page 46.
3.
Remove the turbine alternator (19) from the power
supply, page 47.
4.
Measure resistance from the power supply's ground
strips (EE) to the spring (18b). See F
5.
The resistance should be 95-105 megohms. If out-
side this range, replace the power supply. If in
range, proceed to the next test.
6.
Be sure the spring (18b) is in place before reinstall-
ing the power supply.
Fig. 18. Test Power Supply Resistance
ti1599a
EE
18b
See also other documents in the category HP Tools:
- LSGX203M (39 pages)
- 288048 (30 pages)
- A3312AZ (149 pages)
- R5500 (61 pages)
- R1500 (49 pages)
- PROCURVE 2610 (112 pages)
- COMBI 2180206H (36 pages)
- A1354A (120 pages)
- Power Management System (32 pages)
- Power Management (27 pages)
- C4788x (37 pages)
- 6621A (115 pages)
- 6631B (75 pages)
- Anab EQ Series (131 pages)
- T2200 (55 pages)
- T1500 (48 pages)
- Aikido Stereo 9-Pin PCB (13 pages)
- GMAX 5900 (28 pages)
- Teco MA7200 Plus (12 pages)
- R2200 (61 pages)
- 4445-95 (5 pages)
- 32A (7 pages)
- AUTOMATIC XT SPAY GUNS 311051D (38 pages)
- X09 (54 pages)
- R12000 XR (69 pages)
- Paslode 403606-10 (15 pages)
- Extech 380976 (20 pages)
- XLWW (10 pages)
- T2200 XR (51 pages)
- SCSI (48 pages)
- 39-1572 (10 pages)
- 2995 (20 pages)
- Insight Control (60 pages)
- Insight Control (64 pages)
- Software HP Matrix Operating Environment (65 pages)
- Insight Control (81 pages)
- Insight Control (16 pages)
- Insight Control (75 pages)
- Insight Control (18 pages)
- Insight Control (82 pages)
- Insight Control (54 pages)
- Insight Control (46 pages)
- Insight Control (54 pages)
- Insight Control (77 pages)