Hitachi L300P User Manual
Page 201

L300P Inverter
Motor C
ontrol
Acc
e
ssor
ies
5–11
The table below lists the performance of 400V-class inverter models with the optional external
braking units. In some cases, the resistor selection specifies multiple resistors in a parallel,
series, or combination parallel/series configuration. The example diagram shows a combination
parallel / series configuration. Please refer to the braking unit manual for detailed wiring
diagrams.
Braking
Unit
HRB3 x (6)...
(3) parallel x 2 series
Inverter
Example configuration
400V Class
Braking Unit
Dynamic Braking Resistor Selection
Max.
Braking
Torque,
%
Model Number
L300P
Type
Type
x (quantity)
Series /
Parallel
Total
Ohms
Total
Watts
Max.
Duty
Cycle,
%
–185HFU2,
HFE2
BRD–EZ2
HRB1 x (2)
series
100
800
10
40
HRB2 x (2)
series
70
1200
10
50
HRB3 x (2)
series
34
2400
10
90
BRD–EZ2–30K
HRB3 x (4)
(2) parallel
x 2 series
17
4800
10
170
HRB3 x (6)
(3) parallel
x 2 series
11.3
7200
10
200
–220HFU2,
HFE2
BRD–EZ2
HRB1 x (2)
series
100
800
10
35
HRB2 x (2)
series
70
1200
10
45
HRB3 x (2)
series
34
2400
10
80
BRD–EZ2–30K
HRB3 x (4)
(2) parallel
x 2 series
17
4800
10
150
HRB3 x (6)
(3) parallel
x 2 series
11.3
7200
10
200
–300HFU2,
HFE2
BRD–EZ2–55K
HRB3 x (4)
(2) parallel
x 2 series
17
4800
10
110
HRB3 x (6)
(3) parallel
x 2 series
11.3
7200
10
170
–370HFU2,
HFE2
BRD–EZ2–55K
HRB3 x (4)
(2) parallel
x 2 series
17
4800
10
90
HRB3 x (6)
(3) parallel
x 2 series
11.3
7200
10
150
–450HFU2,
HFE2
BRD–EZ2–55K
HRB3 x (4)
(2) parallel
x 2 series
17
4800
10
70
HRB3 x (6)
(3) parallel
x 2 series
11.3
7200
10
120
–550HFU2,
HFE2
BRD–EZ2–55K
HRB3 x (4)
(2) parallel
x 2 series
17
4800
10
60
HRB3 x (6)
(3) parallel
x 2 series
11.3
7200
10
100