Pump matrix - 2150, Available configurations – Hitachi FD2 1590 User Manual
Page 42

Pump Matrix - 2150
42
311879F
Pump Matrix - 2150
2150 FDA-Compliant Stainless Steel Sanitary Pumps
Your Model No. is marked on the pump’s serial plate. To
determine the Model No. of your pump from the follow-
ing matrix, select the six digits which describe your
pump, working from left to right. The first three digits are
always FD3, designating 2150 SST FDA compliant dia-
phragm pumps. The remaining three digits define the
materials of construction. For example, a pump with an
aluminum air motor, stainless steel fluid section, stain-
less steel seats, PTFE o-rings, PTFE balls, and PTFE
diaphragms is Model No.
FD3111.
To order replace-
ment parts, refer to the part lists on pages 45-46.
The digits in the matrix do not correspond to the refer-
ence numbers in the parts drawings and parts lists.
Available Configurations
• FD3111
• FD3122
• FD3211
• FD3222
• FD3113
• FD3213
• FD3132
• FD3232
FDA-Compliant
Diaphragm
Pump
2150 Stainless
Steel Air Motor
Stainless Steel
Fluid Section
Seats and
O-rings
Balls
Diaphragms
FD3 - All 2150 SST FDA-Compliant Pumps
1 (316 SST with
PTFE o-rings)
1 (PTFE)
1 (PTFE)
2 (316 SST with
EPDM o-rings)
2 (Santoprene®)
2 (Santoprene®)
3 (Neoprene
with SST core)
3 (PTFE
Heavy-Duty)