beautypg.com

Step 1, Step 2, Step 3 – haier HBF205E User Manual

Page 10: Step 4

background image

Clear Hose

Small Barb

STEP 1

DO NOT TURN ON GAS YET

Connect the CO

2

regulator to tank by

screwing regulator nut onto threaded tank

valve. HAND TIGHTEN ONLY – it is not

necessary to use a wrench to tighten this

nut. At this point make sure that both the

shut off (black) valves are in the off (side-

ways) position.

STEP 2

Attach one red gas hose to each of the shut off valve

outlets on the bottom of the regulator and clamp tight

using two of the white squeeze clamps provided.

STEP 3

Attach the other end of each red

gas hose to

the LARGER of the two hose barbs

on the keg coupler and secure with

the remaining two white squeeze

clamps.

STEP 4

Locate the two clear hoses from

the draft arm

installed previously.

(These should be inside the refrigerator at this point). Attach one clear

beer hose to the SMALLER hose barb on each keg coupler being

certain to push the hose completely onto the barb. This connection

does not require a white squeeze clamp.

9

C0

2

Cylinder

Clamp

Red

Hose

Large Barb

Keg Coupler

English