750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)

Maximum Peak Power

For 1200 W Power Supply:
800 W (at 100 VAC),
900 W (at 120 VAC),
1200 W (at 200 to 240 VAC)
For 750 W Power Supply:
750 W (at 100 to 120 VAC),
750 W (at 200 to 240 VAC)
For 460 W Power Supply:
460 W (at 100 to 120 VAC),
460 W (at 200 to 240 VAC)

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature Operating

10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).

Non-operating

-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).

Relative Humidity

Relative Humidity

Relative Humidity

Relative Humidity
(non-condensing)

Operating

10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.

Non-operating

5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.

Altitude

Altitude

Altitude

Altitude

Operating

3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).

Non-operating

9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).

Acoustic Noise

Acoustic Noise

Acoustic Noise

Acoustic Noise

Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23°C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).

NOTE:

NOTE:

NOTE:

NOTE: The Listed sound levels apply to standard shipping configurations.
Additional options may result in increased sound levels.

Idle

Idle

Idle

Idle

1P SKU

1P SKU

1P SKU

1P SKU

2P SKU

2P SKU

2P SKU

2P SKU

LWAd

4.1 B

4.7 B

LpAm

22 dBA

28 dBA

QuickSpecs

HP ProLiant DL380 Generation 6 (G6)

HP ProLiant DL380 Generation 6 (G6)

HP ProLiant DL380 Generation 6 (G6)

HP ProLiant DL380 Generation 6 (G6)

Technical Specifications

DA - 13234 North America — Version 25 — December 18, 2009

Page 53