background image

QuickSpecs

hp StorageWorks

modular SAN array 1000

specific for Tru64 UNIX and OpenVMS only

DA-11621

Canada — Version 2 — April 15, 2003

15

Technical Specifications

M

O D U L A R

S A N A

R R A Y

1 0 0 0

LED Indicators on Front (3)

Power

Fault detected in one or more sub-systems

Fault in Enclosure Management

Drive Access (centre)

LED Indicators for Drive
Modules
(3)

Online (left)
Drive Failure (right)

Power Supply/Blower Assembly Fault (1)

LED Indicators on Rear Panel
(4)

EMU (3) Power, A bus, B bus

Interface

Ultra3 SCSI to Hard Drives

2 Gb Fibre Channel to Hosts

Maximum Number of Drives

Fourteen, 1-inch HP Ultra2, Ultra3 or Ultra 320 Universal Hard Drives (msa1000 Cabinet); expandable to 42 using
two additional StorageWorks 4200/4300 Enclosures

Temperature Range

Operating

50

°

to 95

°

F/10

°

to 35

°

C

Shipping

–22

°

to 122

°

F/–30

°

to 50

°

C

NOTE: Derated 1

°

C per 1,000 feet of elevation to 10,000 ft.

Relative Humidity

Operating

10% to 90%

Non-operating

Up to 95%

Input Power Requirements

Rated Input Voltage

100 to 240 VAC

Rated Input Frequency

50 to 60 Hz

Rated Input Current

6 A Max

Input Power (max)

549 W

*

Heat Dissipation (max)

1876 Btu/hr

*

* Input Power and Heat Dissipation specifications are maximum values and apply to worst-case conditions at full
rated power supply load. The power/heat dissipation for your installation will vary depending on the equipment
configuration.

msa1000 Cabinet

4U Rack Form Factor

Dimensions (H x W x D)

6.9 x 19 x 20.5 in/17.5 x 48.3 x 52.1 cm

Weight

Net 55 to 85 lb/24.95 to 38.56 kg

Shipping Packaging

Dimensions (L x W x D)

28.5 x 14.81 x 33.13 in/72.4 x 37.6 x 84.1 cm

Weight

Gross 75 to 105 lb/34.02 to 47.63 kg