Fig. 5, Fig. 4 – Hoshizaki FD-1001MWH(-C) EN User Manual

Page 62

background image

62

4) Infrared Sensor (K6 connector): Check that the infrared sensor green LED is on.

If not, check for 20VDC from the black K6 connector dark blue wire (DBU) to the
K6 connector brown (BR) wire. See Fig. 4. If 20VDC is not present, the control board is
bad and must be replaced. Next, confirm that the yellow LED is not flashing or steady.
If IS yellow LED is on or flashing, move ice away from IS lens. If no ice is present,
clean the lens with a warm, clean damp cloth. If cleaning the lens does not work,
replace IS.

Red positive test lead to white
K5 connector pin closest to
red K4 connecotor

Fig. 5

Control Board K9 Connector

Red Positive
Test Lead

Black Negative
Test Lead

Multimeter

Fig. 4

Red Positive
Test Lead

Black Negative
Test Lead

20VDC

Multimeter

5) 5VDC control board switch output checks: Control Switch, High Pressure Switch, Gear

Motor Protect Relay (terminals 3 & 5), Mechanical Bin Control Proximity Switch, and
Float Switch.
When checking 5VDC control voltage, always place the red positive test lead from the
multimeter to the white K5 connector pin closest to the red K4 connector. See Fig. 5.
Then place the black negative test lead from the multimeter to the corresponding pin
to complete the 5VDC check. If the icemaker is in alarm (beeping), see "II.C.2.g) LED
Lights and Alarm Safeties Chart."

Infrared Sensor (20VDC)
Open (yellow LED flashing or steady)
20VDC DBU to BR
0VDC DBU to W
20VDC W to BR

Infrared Sensor (20VDC)
Closed
20VDC DBU to BR
20VDC DBU to W
0VDC W to BR

Brown (BR)

Dark Blue (DBU)

White (W)

K6 Connector

Infrared Sensor

5VDC

Control Switch
white/black (W/BK)

High-Pressure Switch
yellow (Y) wires

Gear Motor Protect Relay
(terminals #3 and #5)
white/orange (W/O)