6. FD-1001MRH-C (remote air-cooled)

AC SUPPLY VOLTAGE

208-230/60/1 (3 wire with neutral for 115V)

COMPRESSOR

240 V

4.2 RLA

34 LRA

GEAR MOTOR

120 V

3 FLA

1/4 HP

FAN MOTOR REMOTE

115 V

3A

MAX

OTHER

120 V

0.03A

MAXIMUM FUSE SIZE

15 A

MAX. HACR BREAKER (USA ONLY)

15 A

MAX. CIRC. BREAKER (CANADA ONLY)

15 A

MINIMUM CIRCUIT AMPACITY

15 A

APPROXIMATE ICE PRODUCTION

Ambient

WATER TEMP. (°F)

PER 24 HR.

Temp.(°F)

50

70

90

lbs./day ( kg/day )

70

*930 (423) 895 (406)

860 (390)

Reference without *marks

80

825 (375)

790 (360)

760 (345)

90

730 (332)

*720 (326) 670 (306)

100

645 (294)

620 (282)

*580 (263)

SHAPE OF ICE

Cubelet

ICE QUALITY

Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)

APPROXIMATE STORAGE CAPACITY

N/A

ELECTRIC & WATER CONSUMPTION

90/70°F

70/50°F

ELECTRIC W (kWH/100 lbs.)

1449 (4.8)

1401 (3.6)

POTABLE WATER

86 (12)

112 (12)

gal./24HR (gal./100 lbs.)

EXTERIOR DIMENSIONS (WxDxH)

22" x 24" x 25-15/16" (560 x 610 x 658mm)

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

WEIGHT

Net 176 lbs. ( 80 kg ), Shipping 205 lbs. ( 93 kg )

CONNECTIONS - ELECTRIC

Permanent - Connection

- WATER SUPPLY

Inlet 1/2" FPT

- DRAIN

Outlet 3/4" FPT

- REFRIGERATION

Discharge line 1-1/16-12 UNF Fitting (#10 AEROQUIP)

CIRCUIT

Liquid line 5/8-18 UNF Fitting (#6 AEROQUIP)

ICE MAKING SYSTEM

Auger type

HARVESTING SYSTEM

Direct Driven Auger ( 1/4 HP Gear Motor )

ICE MAKING WATER CONTROL

Float Switch

COOLING WATER CONTROL

N/A

BIN CONTROL SYSTEM (PRIMARY)

Photoelectric Sensor

BIN CONTROL SYSTEM (SECONDARY)

Mechanical Bin Control (Proximity Sw.)

COMPRESSOR

Hermetic, Model RS70-C1E-PFV

CONDENSER

Air-cooled Remote Condenser unit URC-5F Recommended

EVAPORATOR

Copper Tube on Cylinder

REFRIGERANT CONTROL

Thermostatic Expansion Valve

Condensing Pressure Regulator on URC-5F

REFRIGERANT CHARGE

R-404A,

4 lb.1oz.

(1850g)

(Ice Maker: 2 lb. 3 oz., Cond. Unit: 1 lb. 14 oz. )

DESIGN PRESSURE

High 427 PSIG, Low 230 PSIG

P.C. BOARD CIRCUIT PROTECTION

High Voltage Cut-off Relay

COMPRESSOR PROTECTION

Internal Protector

GEAR MOTOR PROTECTION

Fuse (3A)

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

LOW WATER PROTECTION

Float Switch and Timer

ACCESSORIES -SUPPLIED

Spare Fuse

-REQUIRED

Ice Storage Bin

OPERATING CONDITIONS

VOLTAGE RANGE

187-253 V

AMBIENT TEMP.

45-100° F

WATER SUPPLY TEMP.

45-90° F

WATER SUPPLY PRESSURE

10-113 PSIG