6. FD-1001MRH-C (remote air-cooled)
AC SUPPLY VOLTAGE
208-230/60/1 (3 wire with neutral for 115V)
COMPRESSOR
240 V
4.2 RLA
34 LRA
GEAR MOTOR
120 V
3 FLA
1/4 HP
FAN MOTOR REMOTE
115 V
3A
MAX
OTHER
120 V
0.03A
MAXIMUM FUSE SIZE
15 A
MAX. HACR BREAKER (USA ONLY)
15 A
MAX. CIRC. BREAKER (CANADA ONLY)
15 A
MINIMUM CIRCUIT AMPACITY
15 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*930 (423) 895 (406)
860 (390)
Reference without *marks
80
825 (375)
790 (360)
760 (345)
90
730 (332)
*720 (326) 670 (306)
100
645 (294)
620 (282)
*580 (263)
SHAPE OF ICE
Cubelet
ICE QUALITY
Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1449 (4.8)
1401 (3.6)
POTABLE WATER
86 (12)
112 (12)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
22" x 24" x 25-15/16" (560 x 610 x 658mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 176 lbs. ( 80 kg ), Shipping 205 lbs. ( 93 kg )
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet 1/2" FPT
- DRAIN
Outlet 3/4" FPT
- REFRIGERATION
Discharge line 1-1/16-12 UNF Fitting (#10 AEROQUIP)
CIRCUIT
Liquid line 5/8-18 UNF Fitting (#6 AEROQUIP)
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 1/4 HP Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM (PRIMARY)
Photoelectric Sensor
BIN CONTROL SYSTEM (SECONDARY)
Mechanical Bin Control (Proximity Sw.)
COMPRESSOR
Hermetic, Model RS70-C1E-PFV
CONDENSER
Air-cooled Remote Condenser unit URC-5F Recommended
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
Condensing Pressure Regulator on URC-5F
REFRIGERANT CHARGE
R-404A,
4 lb.1oz.
(1850g)
(Ice Maker: 2 lb. 3 oz., Cond. Unit: 1 lb. 14 oz. )
DESIGN PRESSURE
High 427 PSIG, Low 230 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-off Relay
COMPRESSOR PROTECTION
Internal Protector
GEAR MOTOR PROTECTION
Fuse (3A)
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch and Timer
ACCESSORIES -SUPPLIED
Spare Fuse
-REQUIRED
Ice Storage Bin
OPERATING CONDITIONS
VOLTAGE RANGE
187-253 V
AMBIENT TEMP.
45-100° F
WATER SUPPLY TEMP.
45-90° F
WATER SUPPLY PRESSURE
10-113 PSIG
ENG F-013.0.1196