APPROXIMATE
Ambient
Water Temp. (°F)
ICE PRODUCTION
Temp. (°F)
PER 24 HR.
70
*930
*(423)
895
(406)
860
(390)
80
825
(375)
790
(360)
760
(345)
90
730
(332)
*720 *(326)
670
(306)
lbs./day (kg/day)
100
645
(294)
620
(282)
*580 *(263)
APPROXIMATE ELECTRIC
70
*1401
--
1408
--
1415
--
CONSUMPTION
80
1422
--
1428
--
1435
--
90
1442
--
*1449
--
1444
--
watts
100
1440
--
1435
--
*1430
--
APPROXIMATE WATER
70
*112 *(423)
108
(406)
103
(390)
CONSUMPTION PER 24 HR.
80
99
(375)
95
(360)
91
(345)
90
88
(332)
*86
*(326)
81
(306)
gal./day (l/day)
100
78
(294)
75
(282)
*70
*(263)
EVAPORATOR OUTLET TEMP.
70
*5
*(-15)
5
(-15)
5
(-15)
80
5
(-15)
9
(-13)
9
(-13)
90
9
(-13)
*9
*(-13)
12
(-11)
°F (°C)
100
12
(-11)
12
(-11)
*12
*(-11)
HEAD PRESSURE
70
*205 *(14.4)
205
(14.4)
205
(14.4)
80
234
(16.5)
234
(16.5)
234
(16.5)
90
264
(18.6)
*264 *(18.6)
264
(18.6)
PSIG (kg/cm²G)
100
301
(21.1)
301
(21.1)
301
*(21.1)
SUCTION PRESSURE
70
*33
*(2.3)
33
(2.3)
33
(2.3)
80
35
(2.4)
35
(2.4)
35
(2.4)
90
36
(2.6)
*36
*(2.6)
36
(2.6)
PSIG ( kg/cm²G )
100
39
(2.7)
39
(2.7)
*39
*(2.7)
CONDENSER VOLUME
74.5 cu in
HEAT OF REJECTION FROM CONDENSER 8900 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR 1400 BTU/h (AT 90°F /WT 70°F)
50
70
90
Note: We reserve the right to make changes in specifications and design without prior
notice.
6. FD-1001MRH-C (remote air-cooled)