Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA
74) and declared in accordance with ISO 9296 (ECMA 109).
Idle
LWAd
6.25 B
LpAm
51.4dBA
Operating
LWAd
6.25 B
LpAm
51.4 dBA
Emissions
Classification (EMC)
FCC Rating
Class A
Normative Standards
CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; CNS13438; GB9254;
K22;K24; EN 61000-3-2; EN 61000-3-3; EN
60950-1; IEC 60950-1
NOTE: Product conformance to cited product specifications is based on
sample (type) testing, evaluation, or assessment. This product or family
of products is eligible to bear the appropriate compliance logos and
statements.
Power Supply
Input voltage
specifications
Rated input voltage
100 VAC to 240 VAC
Input Specifications
Rated input line
90 VAC to 264VAC
Frequency range
47 to 63 Hz
Rated input power
@ 115V input, Rated input power = 486W
(assume output wattage=450W
@ 230V input, Rated input power = 479W
(assume output wattage=450W)
Rated input current
6 A, 3 A (110 V, 220 V)
Steady state power
420W (rated)
BTU Rating
1710 BTU/hr
Ambient temperature
range
Operating
50° to 118° F (10° to 48° C)
Non-operating
-40° to 158° F (-40° to 70° C)
Relative humidity
(non-condensing)
Operating
55% to 85%
Non-operating
5% to 95%
Dielectric voltage
withstand
Input to output
1800 VAC/minute
Input to ground
1800 VAC/minute
Maximum Wet Bulb
Temperature
106.3° F (41.3° C)